Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Data Brief ; 53: 110227, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38435737

RESUMO

This paper shares an experimental dataset of lithium-ion battery parallel-connected modules. The campaign, conducted at the Stanford Energy Control Laboratory, employs a comprehensive full factorial Design of Experiment methodology on ladder-configured parallel strings. A total of 54 test conditions were investigated under various operating temperatures, cell-to-cell interconnection resistance, cell chemistry, and aging levels. The module-level testing procedure involved Constant Current Constant Voltage (CC-CV) charging and Constant Current (CC) discharge. Beyond monitoring total module current and voltage, Hall sensors and thermocouples were employed to measure the signals from each individual cell to quantify both current and temperature distribution within each tested module configuration. Additionally, the dataset contains cell characterization data for every cell (i.e. NCA Samsung INR21700-50E and NMC LG-Chem INR21700-M50T) used in the module-level experiments. This dataset provides valuable resources for developing battery physics-based, empirical, and data-driven models at single cell and module level. Ultimately, it contributes to advance our understanding of how cell-to-cell heterogeneity propagates within the module and how that affects the overall system performance.

2.
J Vasc Surg ; 79(2): 217-227.e1, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37852334

RESUMO

OBJECTIVE: To investigate the effect of narrow paravisceral aorta (NPA) on target vessel instability (TVI) after fenestrated-branched endovascular aortic repair. METHODS: We conducted a single-center retrospective study (2014-2023) of patients treated by fenestrated-branched endovascular aortic repair for thoracoabdominal aortic aneurysms (TAAA) or pararenal aortic aneurysms. The paravisceral aorta was defined as the aortic segment limited by the diaphragmatic hiatus proximally and the emergence of lower renal artery distally, and was considered "narrow" in case of a minimum inner diameter of <25 mm. The minimum aortic diameter, location, longitudinal extension, angulation, calcification, and thrombus thickness of NPA were evaluated at the preoperative computed tomography angiogram. End points were 30-day technical success and freedom from TVI. RESULTS: There were 142 patients with JRAA/pararenal aortic aneurysm (n = 85 [59%]) and extent IV (n = 24 [17%]) or extent I-III (n = 33 [23%]) TAAA, with 513 target arteries successfully incorporated through a fenestration (n = 294 [57%]) or directional branch (n = 219 [43%]). A NPA was present in 95 patients (70%), 73 (86%) treated by fenestrated endovascular aortic repair (FEVAR) and 22 (39%) by branched endovascular aortic repair (BEVAR). The overall 30-day mortality was 2% and technical success was 99%, without differences between NPA and non-NPA (P = .99). Kaplan-Meier estimated freedom from TVI at 4 years was 82%, 81% (95% CI, 75-95) in patients with a NPA and 80% (95% CI, 68-94) and in those without NPA (P = .220). The result was maintained for both FEVAR (NPA: 81% [95% CI, 62-88]; non-NPA: 76% [95% CI, 60-99]; P = .870) and BEVAR (NPA: 77% [95% CI, 69-99]; non-NPA: 80% [95% confidence interval (CI) 66-99]; P = .100). After multivariate analysis, the concomitant presence of a NPA <20 mm and angulation of >30° was significantly associated with TVI in FEVAR (HR, 3.21; 95% CI, 1.03-48.70; P = .036), being the result mostly driven by target vessel occlusion. In BEVAR, a NPA diameter of <25 mm was not associated with TVI (HR, 2.02; 95% CI, 0.59-5.23; P = .948); after multivariate analysis, the use of outer branches in case of a NPA longitudinal extension of >25 mm (hazard ratio [HR], 3.02; 95% CI, 1.01-36.33; P = .040) and NPA severe calcification (HR, 1.70; 95% CI, 1.00-22.42; P = .048) were associated with a higher chance for TVI. CONCLUSIONS: FEVAR and BEVAR are both feasible in cases of NPA and provide satisfactory target vessels durability. The use of outer branches should be avoided in cases with an inner aortic diameter of <25 mm with a longitudinal extension of >25 mm or moderate to severe NPA calcifications. In FEVAR, bridging stent patency may be negatively influenced by NPA of <20 mm in association with aortic angulation of >30°.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Correção Endovascular de Aneurisma , Prótese Vascular , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/etiologia , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Fatores de Tempo , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Aorta/cirurgia
3.
Data Brief ; 52: 109798, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38076480

RESUMO

The data reported here was prepared to study the effects of calendering process on NMC622 cathodes using a 3-3-2 full factorial design of experiments. The data set consists of 18 unique combinations of calender roll temperature (85 °C, 120 °C, or 145 °C), electrode porosity (30%, 35%, or 40%), and electrode mass loading (120 g/m² or 180 g/m²). The reported physical characteristics of the electrodes include thickness, coating weight, maximum tensile strength, and density. The electrochemical performances of the electrodes were obtained by testing coin cells. In this context, 54 half-cells were produced, 3 per each calendering experiment to ensure repeatability and reliability of the results. The responses of interest included, charge energy capacity at C/2, C/5, discharge energy capacity at C/20, C/5, C/2, C, 2C, 5C, 10C, gravimetric capacity (charge at C/2, C/5, discharge at C/20, C/5, C/2, C, 2C, 5C, 10C), volumetric capacity (charge at C/2, C/5, discharge at C/20, C/5, C/2, C, 2C, 5C, 10C), rate performance (5C:0.2C), area specific impedance (at 10% to 90% state of charge (SoC) in 10 breakpoints), long-term cycling capacity (charge at C/5 for 50 cycles, discharge at C/2 for 50 cycles), long-term cycling degradation (at C/2 during 50 cycles of charge and discharge), and cycling columbic efficiency (50 cycles of C/2 charge and discharge). The details of the experimental design that has led to this data as well as comprehensive statistical analysis, and machine learning-based models can be found in the recently published manuscripts by Hidalgo et al. and Faraji-Niri et al. [1,2].

4.
J Vasc Surg Cases Innov Tech ; 9(3): 101215, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37408941

RESUMO

We describe the feasibility of a technique for temporary aneurysm sac reperfusion after endovascular single-stage thoracoabdominal aortic aneurysm exclusion, to be used in the case of postoperative spinal cord ischemia. Two cases were treated for impending rupture of a thoracoabdominal aortic aneurysm. Before completion of sac exclusion, a supplementary buddy wire (V-18 control guidewire; Boston Scientific) was advanced in parallel fashion from the left percutaneous femoral access into the aneurysmal sac on the posterior aspect of the endograft. Distal aneurysm exclusion was completed using the main superstiff guidewire, and the femoral access was closed with a percutaneous closure device (ProGlide; Abbott) in standard fashion, leaving in place the sole V-18 guidewire, draped in sterile fashion. In the case of spinal cord ischemia, the "safe-line" can be rapidly used for spinal reperfusion after trans-sealing exchange with a 6F, 65-cm-long Destination sheath (Terumo) connected to a 6F introducer on the contralateral femoral artery.

5.
Data Brief ; 48: 109157, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37383794

RESUMO

This article addresses the objective, experimental design and methodology of the tests conducted for battery State of Health (SOH) estimation using an accelerated test method. For this purpose, 25 unused cylindrical cells were aged, by continual electrical cycling using a 0.5C charge and 1C discharge to 5 different SOH breakpoints (80, 85, 90, 95 and 100%). Ageing of the cells to the different SOH values was undertaken at a temperature of 25 °C. A reference performance test (RPT) of C/3 charge-discharge at 25 °C was performed when the cells were new and at each stage of cycling to define the energy capacity reduction due to increased charge-throughput. An electrochemical impedance spectroscopy (EIS) test was performed at 5, 20, 50, 70 and 95% states of charge (SOC) for each cell at temperatures of 15, 25 and 35 °C. The shared data includes the raw data files for the reference test and the measured energy capacity and the measured SOH for each cell. It contains the 360 EIS data files and a file which tabulates the key features of the EIS plot for each test case. The reported data has been used to train a machine-learning model for the rapid estimation of battery SOH discussed in the manuscript co-submitted (MF Niri et al., 2022). The reported data can be used for the creation and validation of battery performance and ageing models to underpin different application studies and the design of control algorithms to be employed in battery management systems (BMS).

7.
Phys Chem Chem Phys ; 24(48): 29999-30009, 2022 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-36472147

RESUMO

Join counting, a standard technique in spatial autocorrelation analysis, has been used to quantify the clustering of carbon, fluorine and sodium in cross-sectioned anode and cathode samples. The sample preparation and EDS mapping steps are sufficiently fast for every coating from two Design of Experiment (DoE) test matrices to be characterised. The results show two types of heterogeneity in material distribution; gradients across the coating from the current collector to the surface, and clustering. In the cathode samples, the carbon is more clustered than the fluorine, implying that the conductive carbon component is less well distributed than the binder. The results are correlated with input parameters systematically varied in the DoE e.g. coating blade gap, coating speed, and other output parameters e.g. coat weight, and electrochemical resistance.

8.
Data Brief ; 40: 107720, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34988274

RESUMO

Megtec Systems pilot-plant scale continuous convective coater. The data was generated as part of an experimental design involving the following coating-drying process variables and ranges: comma bar gap, 80-140 µm; web speed, 0.5-1.5 m/min; coating ratio, 110-150%; drying temperature, 85-110 °C and drying air speed, 5-15 m/s. The manufacturing data include pre-calendered coating thickness, mass loading dry and wet, pre-calendered porosity, spatial autocorrelation and join counting (SAJC) Z-score for carbon and for fluorine, cell thickness, coating weight and porosity of 15 different electrode coatings and 45 half-coin cells. The electrochemical data was obtained at 25 °C in a Maccor 4000 series battery cycler and consists of charge and discharge capacities at C/20, C/5, C/2, 1C, 2C, 5C and 10C C-rates. Discharge gravimetric and volumetric capacities, rate performance (at 5C:0.2C) and first cycle loss data is also reported. Details of the experimental design and a comprehensive analysis of the data can be found in the co-submitted manuscript (Román-Ramírez et al., 2021). Additional collected data not used in Román-Ramírez et al. (2021) is reported in the present manuscript and include visual observations of coating defects, rheological properties of the electrode slurries (solid content, viscosity, coating shear rate and viscosity at coating shear rate), room temperature and room humidity during the coatings and first cycle loss of the coin cells. Raw and analyzed data is made available. The reported data can be used to extend the analysis reported in Román-Ramírez et al. (2021), and for the comparison of relevant data obtained at different manufacturing scales.

9.
Sensors (Basel) ; 21(14)2021 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-34300374

RESUMO

A method based on equal frequency resampling is proposed to suppress laser nonlinear frequency sweeping for the ultimate spatial resolution in optical frequency domain reflectometry. Estimation inaccuracy of the sweeping frequency distribution caused by the finite sampling rate in the auxiliary interferometer can be efficiently compensated by the equal frequency resampling method. With the sweeping range of 130 nm, a 12.1 µm spatial resolution is experimentally obtained. In addition, the sampling limitation of the auxiliary interferometer-based correction is discussed. With a 200 m optical path delay in the auxiliary interferometer, a 21.3 µm spatial resolution is realised at the 191 m fibre end. By employing the proposed resampling and a drawing tower FBG array to enhance the Rayleigh backscattering, a distributed temperature sensing over a 105 m fibre with a sensing resolution of 1 cm is achieved. The measured temperature uncertainty is limited to ±0.15 °C.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...